2-Hour UL Fire Test
The safe must maintain an interior temperature less than 125°F and an interior
relative humidity less than 80% for class 125, when exposed to fire as per
the Standard Time Temperature Curve for 2 hours to 1850°F. It must undergo
all other requirements for the Fire Endurance Test, the Explosion Hazard
Test, the Humidity Test, and the Fire and Impact Test. Basically, no explosion
through 30 minutes to exposure to a 2000°F fire and immediate 30 foot drop
test and a standard reheating for 45 minutes to 1638°F.
- UL Class 125 2-Hour Fire and Impact Rating
- Tested in Accordance With VDMA 24991 in Class S120DIS and EN1047-1
- RAL9002 Light Gray Color
- Electronic Combination Lock
DS2320-2:
680 lbs, 4.04 cubic feet capacity
Internal Dimensions:
22 1/2" Height
19 5/16" Width
15 13/16" Depth External Dimensions:
36 1/8" Height
29 7/16" Width
30" Depth Interior Options:
CS20-FS Fixed Shelf or
CS20-CD Composite Drawer Interior Capacity:
| ITEM |
QUANTITY |
TOTAL |
| 3.5 Floppy |
5 Drawers @ 608 Each |
3040 |
| 3480 IBM |
4 Drawers @ 51 Each |
204 |
| 4 mm DAT |
5 Drawers @ 124 Each |
620 |
| 8 mm DAT |
5 Drawers @ 79 Each |
395 |
| CD ROM |
3 Drawers @ 117 Each |
351 |
| DLT |
4 Drawers @ 48 Each |
192 |
| PC100 ZIP |
5 Drawers @ 128 Each |
640 |
|
DS3420-2:
880 lbs, 5.41 cubic feet capacity
Internal Dimensions:
33 9/16" Height
19 5/16" Width
15 13/16" Depth External Dimensions:
47 3/16" Height
29 7/16" Width
30" Depth Interior Options:
CS20-FS Fixed Shelf or
CS20-CD Composite Drawer Interior Capacity:
|
ITEM |
QUANTITY |
TOTAL |
| 3.5 Floppy |
9 Drawers @ 608 Each |
5472 |
| 3480 IBM |
6 Drawers @ 51 Each |
306 |
| 4 mm DAT |
9 Drawers @ 124 Each |
1116 |
| 8 mm DAT |
9 Drawers @ 79 Each |
711 |
| CD ROM |
5 Drawers @ 117 Each |
585 |
| DLT |
7 Drawers @ 48 Each |
336 |
| PC100 ZIP |
7 Drawers @ 128 Each |
896 |
|
|